Two models of this product are available depending on demands in
target application. The lower range model has a lower scale factor
(higher resolution) and better performance in regards to noise. A
SPI interface enables easy and effective communication between
customer application and sensor. A number of functions are
available through the digital SPI interface including advanced self
diagnostics.
| Parameter |
Min |
Typ |
Max |
Unit |
Comment |
Range SAR10
Range SAR10H
|
|
±250
±100 |
|
°/s
|
|
| Output |
|
10
|
|
bit
|
2's complement
|
Scale factor SAR10H
Scale factor SAR10
|
|
0.4
1.0
|
|
°/s / LSB
|
|
Sampling frequency
|
|
|
2000
|
SPS
|
Nominal value
|