SAR100 is offered in two different ranges, has DC response, with
low bias drift and noise, and incorporates a temperature sensor. A
SPI interface enables easy and effective communication between
customer application and sensor. A number of functions are
available through the digital SPI interface including advanced self
diagnostics.
| Parameter |
Min |
Typ |
Max |
Unit |
Comment |
|
Range
Range
Range
|
|
±400
±250
±100
|
|
°/s
|
|
| Output |
|
12
|
|
bit
|
2's complement
|
|
Scale factor ±400
Scale factor ±250
Scale factor ±100
|
|
0.25
0.25
0.10
|
|
°/s / LSB
|
|
In-run bias stability
|
|
0.02
|
|
°/s
|
|
|
Noise ±400°/s
Noise ±250°/s
Noise ±100°/s
|
|
0.25
0.25
0.15
|
|
°/s(rms)
|
|
Rate noise density ±400°/s
Rate noise density ±250°/s
Rate noise density ±100°/s
|
|
0.03
0.03
0.02
|
|
°/s/√Hz
|
|
Sampling frequency
|
|
|
2000
|
SPS
|
Nominal value
|